| ![]() MIL-S-63348A(AR)
REQUIRE-
INSP
DEFECT
MINOR
METHOD
MENT
MAJOR
DEFECT
No.
3.7
x
Trigger group. Burrs, cracks Visual
7.
or mutilation of catch
surface, and safety contact
surface.
x
Visual
3.7
Trigger group. Mutilation
8.
distortion, or improper
assembly of trigger spring.
x
3.3.2.3
Manual
Selector group. Failure of
9.
3.3.2.4
spring loaded detect plunger
to positively engage selector
lever, when lever is in safe,
and automatic position.
x
3.7 and
Visual
10.
Selector group. Burrs,
drawing
cracks, or mutilation of
selector lever, and sear
contact surfaces. Missing
lubricant.
x
3.3.2.5
Manual
11.
Bolt catch qroup. Failure
of catch to pivot upward
when lower button is pressed,
and failure of catch to
return to original position
under spring load when.
pressure of button is released.
x
3.7
Visual
12.
Bolt catch group. Burrs,
cracks, or mutilation of
bolt contact surface.
x
3.3.2.6
Visual
13.
Magazine release button_.
Improper adjustment of
magazine. release button.
17
|