| MIL-S-64045 (AR)
TABLE I. CLASSIFICATIION
OF DEFECTS
CHARACTERISTIC
REQUIREMENT
TEST PROCEDURE
CLASS
CRITICAL:
NONE
MAJOR: AQL 1.0 PERCENT DEFECTIVE
Printing and Surface quality
3.7
4.6.6
101.
Scales
3.8
4.6.7
102.
3.9
4.6.8
Graduation errors
103.
4.6.8.1
Accuracy
104.
3.10
4.6.9
4.6.9.1
4.6.9.2
105.
Operability
3.11
4.6.10
MINOR:
NONE
4.3.3 Acceptance and Rejection. Rejected lots shall be
screened for all defect characteristics. Removal for correction
of defective units and resubmittance of rejected lots shall be in
accordance with "Acceptance and Rejection" as specified in
MIL-STD-105.
4.4 Special Sampling. Three graphical firing scales shall be
selected at random from each 50 produced or from each month,
whichever occurs first. The special samples shall have
successfully met all acceptance tests specified herein prior to
conducting the following examinations and tests in table II
TABLE II
REQUIREMENT
TEST PROCEDURE
NO.
CHARACTERISTIC
4.6.1
3.3
Fabrication
301
3.4 c & d
Visual,
302
General Specification
MIL-F-13926
4.6.2
3.5.1
Storage Temperature
303
4.6.3
Operating Temperature
3.5.2
304
4.6.4
3.5.3
305
Humidity
4.4.1 Failure of Sample. Should any one item of a special
sampling fail to meet the specified test requirements, acceptance
of the product shall be suspended by the government until
necessary corrections have been made by the contractor and
resubmitted samples have been approved (see 4.3.3).
4.5 Inspection Equipment. Except as otherwise provided for by
the contract, the contractor shall supply equipment to perform all
the inspections and tests referenced and as stated in the contract.
6
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |