4.4 Quality conformance inspection.
4.4.1 Inspection lot formation.
Inspection lots shall comply
with the lot formation provisions of MIL-A-48078. In addition,
inspection lots of Simulator Assemblies shall contain:
a.
Parts of one kind from one manufacturer.
b. Electric match from not more than one lot interfix number
from one manufacturer.
Composition ingredients from not more than one lot or
co
batch.
4.4.2 Examination.
- See MIL-A-48078.
a. Sampling plans . Unless otherwise specified in the
Classification of Defects and Test tables, sampling plans and
procedures for major and minor defects shall be in accordance with
MIL-STD-105.