WRA. The HSSS shall interface with Antenna AS-2764( )/
3.2.1.12.1
AWG-9 through two hydraulic connections.
Electrical power. The HSSS shall interface with the electrical
3.2.1.12.2
power of 3.2.2.1 through the cable of 3.6.14.
Utilities. Applicable.
3.2.2
Electrical power. Electrical power required for operation
3.2.2.1
of the HSSS shall be not more than 300-volt-amperes of 115-volt, 400 Hertz (Hz),
single phase power. This alternating current (ac) power form shall conform to
MIL-STD-761, Type I.
3.2.2.2
Clean air. Not applicable.
Potable water. Not applicable.
3.2.2.3
Liquid coolant. Not applicable.
3.2.2.4
Helium. Not applicable.
3.2.2.5
3.2.2.6
Nitrogen.
Not applicable.
3.2.2.7
Hydraulic fluid. Applicable.
3.2.3.
Service conditions. Applicable.
3.2.4
Maintainability.
Applicable.
3.2.5
Reliability. Applicable. The mean time between failures
(MTBF) shall be 500 hours minimum.
3.2.6
Electromagnetic interference (EMI). Not applicable.
3.2.7
Utilities protection. Applicable.
3.2.7.1
Liquid cooling protection. Not applicable.
3.2.7.2
Clean air protection. Not applicable.
3.2.7.3
Electrical po wer protection.
Applicable.
3.2.8
Calibration cycle. Applicable. Calibration requirements and
requirements for support equipment to maintain the HSSS will be stated in the Test Set
Maintenance Engineering Analysis (MEA). Procedures will be stated in the Technical
Manuals.
3.2.9
Fluid capacity and filtration. The HSSS shall provide
storage for one gallon of hydraulic fluid and shall provide fluid filtration of 3
microns absolute.