| MIL-S-81775B(AS)
Three micron absolute filter. A three micron absolute full
3.6.9
flow filter shall provide filtration of the hydraulic fluid.
Differential pressure indicator. The differential pressure
3.6.10
indicator shall indicate, by a visual pop-up indication, when pressure drop due to
contamination of the filter of 3.6.9 exceeds 80 12 psi.
Flexible hoses. Two flexible hoses shrill be provided, each
3.6.11
10 1 feet in length. The hoses shall have quick-disconnect fittings to mate with
the radar antenna hydraulic system.
Hydraulic pump switch. The hydraulic pump switch shall be
3.6.12
a panel mounted toggle switch and shall control electrical power to the HSSS.
Elapsed time indicator. An elapsed time meter conforming
3.6.13
to MIL-M-7793 shall be provided. The meter shall be readily visible during operation
of the HSSS and shall be capable of registering at least 9,999 hours.
Power cable. A power cable shrill be provided in accordance with
3.6.14
MILT-21200. The connector shall be MS3107A-16S-8P with MS3057-8A cable clamp.
The connector shall have 115 volts, 400 Hz single phase power on Pin A with the return
on Pin D. The length of the cable shall be 25 0.5 feet.
QUALITY ASSURANCE PROVISIONS
4.
Responsibility for inspection. Applicable.
4.1
4.2
General. Applicable.
Applicable.
4.2.1
Classification.
Individual items. Applicable.
4.2.2
In-process inspection. Applicable.
4.2.3
In-process data. Applicable.
4.2.4
4.2. 5
Acceptance test plan. Applicable. Table I shall apply.
4.2.6
Test results. Applicable.
Applicable.
4.2.7
Acceptance.
4.2.8
Utilities. Applicable.
Configuration.
4.2.9
Applicable.
4.3
Tests
4.3.1
Electrical and electronic items - operational run-in test.
Applicable.
4.3.2
Mechanical items. Applicable.
|