MIL-T-27/306B
Temperature rise: 50C with 36 volts rms, 20 kilohertz square wave across (1-GND) and with 17 to 20 volts
across (2-GND) at an ambient temperature of 80C.
Vibration (high frequency): MIL-STD-202, method 204, test condition A.
Shock (specified pulse): MIL-STD-202, method 213, test condition H.
Quality assurance provisions:
Qualification inspection: Not applicable.
Quality conformance inspection: Groups A and B tests of MIL-PRF-27 shall be applicable.
Marking location: See figure 1.
Part or Identifying Number (PIN): M27/306-01.
Custodians:
Preparing activity:
Army CR
DLA CC
Navy EC
Air Force 11
(Project 5950-1145)
Review activities:
Army AR, CR4, MI
Navy AS, MC, OS, SH
Air Force 19, 99