| MIL-T-45498C
204
Cut, damaged, or improperly sealed bag
Visual
4.5.2.18 Box, Packing, Ammunition, Drawing 8797632.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Visual/Manual
202
Strapping missing, loose, broken, or improperly assembled
Visual/Manual
203
Contents of box exposed
Visual
204
Box damaged
Visual
205
Marking missing, incorrect, or illegible
Visual
206
Number of units incorrect
Visual
4.5.2.19 Box, Fiberboard (Outer), Alternative, Packing, Ammunition, Drawing 9221261.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual/Visual
202
Carton broken or damaged
Visual
203
Number of units incorrect
Visual
204
Marking missing, incorrect, or illegible
Visual
205
Tape incomplete
Visual
4.5.3 Inspection testing. The following tests shall be performed in accordance with 4.6.
4.5.3.1 Hardness. Fifty units from each heat treated lot of components shall be tested for compliance
with the requirements on the applicable drawing. Failure of any unit to comply with the drawing requirements
shall be cause for rejection of the lot of components.
4.5.3.2 Hydrostatic pressure. Each body and end cap shall be subjected to the hydrostatic pressure test.
Failure of any cap or chamber subassembly to comply with 3.4 shall be cause for rejection of the subassembly.
4.5.3.3 Shear pin strength. Fifty pins from each lot of shear pins shall be tested for shear strength.
Failure of any shear pin to comply with 3.5 shall be cause for rejection of the lot.
4.5.3.4 Protective finish. The number of units for protective finish tests shall be in accordance with the
applicable specification. Failure of any unit in the inspection sample to comply with the requirements of the
applicable specification shall be cause for rejection of the lot.
16
|