|
| MIL-T-45499C
4.2.1 Lot.
4.2.1.1 Submission of product. Unless otherwise specified by the contracting activity, formation, and
identification of lots shall be in accordance with MIL-STD-105.
4.2.1.2 Size of lot. The production lot size shall be as specified in the contract (see 6.2).
4.2.2 Examination. One hundred percent examination shall be performed for all critical defects.
Examination for major and minor defects shall be performed in accordance with the classification of defects.
Four power (4x) magnification may be used for inspection of such defects as burr and foreign matter. When
compliance with the applicable requirement is in doubt as a result of visual examination, the characteristic
shall be measured or gaged to determine acceptability. All nonconforming material shall be rejected.
4.2.2.1 Cartridge, Drawing 8593889, covering a detail of Drawing 8593854.
Characteristics
Defect
Method of Inspection
Critical
1
Mixed cartridges
Visual
2
Metal defective
Visual
3
Marking missing, incorrect, or illegible
Visual
Major
101
Foreign matter present
Visual
Minor
201
Case scratched or dented
Visual
4.2.2.2 Firing Pin Guide, Subassembly, consisting of Drawings 8593284, 8593863, 8593864, and
MS28775-012 covering a detail of Drawing 8593854.
Critical
1
Striker hole obstructed
Visual
Major
101
Firing pin base not flush or below firing pin guide
Manual/Visual
102
Foreign matter
Visual
Minor
None defined
4.2.2.3 Assembly, (Head), Drawing 8593854 less all components except Drawings 8593284, 8593862,
8593863, 8593864, 8593889, 8593870, MS28775-012 and MS28775-212.
Critical
5
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |