| MIL-T-46386A(MU)
shall be so selected and controlled as to insure that the test equipment
will reliably indicate acceptability of a product which does not exceed
90% of the prescribed tolerance limit, and permit positive rejection when
non-conforming. Construction shall be such as to facilitate routine
calibration of test equipment.
4.5.3 Test equipment. - In conjunction with 4.5.2.2 the following
standard test equipment shall be utilized in the performance of the applicable
tests as specified in 4.6 and 4.7.
DESCRIPTION
NOMENCLATURE
Standard type conforming to the
1.
Hot & cold chamber
accuracies outlined in test
facilities specified under
test facilities of MIL-F-13926
2 . Continuity checker
Standard shop type capable of
providing readings accurately
within 2% of specified
tolerance
Standard shop type conforming
3 . Insulation resistance checker
to the accuracies outlined
in 4.5.2.2
0 to 100V D. C. output within 10%
4 . Power supply
accuracy
Standard shop type accurate to
5 . Torque wrench and scale
within 10% of drawing tolerance
4.6 Test methods and procedures.
4.6.1 Environmental.
4.6.1.1 Temperature test. - The panoramic telescope shall be subjected
to test Procedure I of MIL-F-13926; however, the temperatures specified
in 3.4.1 and 3.4.2 shall apply. When the panoramic telescope has been
stabilized at the temperature specified, the result of the specified test
shall conform to the limits outlined in 3.4.1 and 3.4.2 using test procedures
outlined herein.
4.6.1.2 Sealing optical assembly. - This test
shall be performed
using testing equipment the accuracy of which shall
conform to the accuracy
depicted on Drawing F8565556. When using pressure
test fixture, the fixture
shall be set-up as outlined in set-up instructions
shown on Drawing F8565556,
10
|