MIL-T-46786B
TABLE V.
Examination.
Requirement
First
Quality
article conformance
Examination description
paragraph
4
2
3
1
x
3.3 and
x
101.
Materials not as specified.
table I
x
102.
Material not resistant to corrosion
3.3.1
and deterioration or treated to be
resistant to corrosion and deteri-
oration for the applicable storage
and operating environments.
x
3.3.1.1
103.
Dissimilar metals as defined in
MIL-STD-889 are not effectively
insulated from each other.
Contractor does not have documen--
x
104.
3.3.1.2
tation available for identification
of material, material finishes, or
treatment.
x
105.
Used, rebuilt or remanufactured
3.3.2
components, pieces, or parts
incorporated in the fuel tank.
x
106.
Threaded parts not as specified.
3.4
3.5.1
x
107.
Baffles not as specified.
x
108.
3.5.2
Filler and fittings not as specified.
3.5.2.1
x
109.
Filler cap not as specified.
x
110.
Captive c hains not as specified.
3.5.2.1
x
111.
Filler neck not as specified.
3.5.2.2
112.
3.5.2.2 &
x
Means of attaching filler neck not
as specified.
table III
3.5.2.3
x
113.
Filler strainer not as specified.
x
114.
3.5.3
Fuel tank drain not as specified.
x
115.
Grounding not as specified.
3.5.7
x
116.
Mounting not as specified.
3.5.8
x
3.5.9
117.
Suction tube or standpipe not as
specified.
118.
Venting not as specified.
x
3.5.10
x
119.
Tank construction not as specified.
3.6
x
120.
Safety features not as specified.
3.7
x
121.
3.9
Identification marking not as
specified.
x
122.
Treatment, painting, and coating
3.10
not as specified.
x
123.
Fuel tank not as specified in the
3.11
applicable standard.
x
124.
Workmanship not as specified.
3.12
4.5.2 Tests.
4.5.2.1 Test conditions.
Tests shall be conducted on completely assembled
fuel tanks.
4.5.2.2 Leakage.  Close all openings in the fuel tank and pressurize the
tank with air to either 7 psig for cylinder and cylindroid tanks or 3 psig for
rectangular tanks.  Examine the fuel tanks for leaks while maintaining the
specified pressure for not less than 5 minutes on first article inspection, and
15