MIL-T-48466B(AR)
4.6.1.3  Dielectric  strength.  Perform a dielectric strength
test between pin 15J2-B and case in accordance with MIL-STD-202,
Method 301, using 2000V rms at a frequency of 60 Hz for a period
During this test, verify that the
1.0 seconds.
of 10.0
electrical wiring within the assembly shows no evidence of
disruptive discharge or leakage current.
4.6.2
Physical
characteristics.
4.6.2.1  Physical characteristics of CTS.  Visually examine
the CTS for conformance to Drawing 11733300 and drawings
referenced therein.
4.6.2.2 Power cables.  Visually examine the power cables for
conformance to Drawings 11732468 and 11732558.
4.6.2.3 Test interconnect-ion cables.  Visually examine the
test interconnection cables for conformance to Drawings 11747425,
11747426,  11747427 and 11747428, respectively.
4.6.2.4 Ammo select cable.  Visually examine the ammo select
cable for conformance to Drawing 11732469.
4.6.2.5  Shorting connectors .  Visually examine the shorting
connectors for conformance to Drawings specified in 3.2.2.5.
4.6.3
Environmental
conditions.
Subject the assembly in its normal
4.6.3.1  Waterproofness.
operating condition to the leakage (immersion) test of MIL-STD-810,
Method 512, except submerge the assembly in water at room
temperature to develop a pressure differential of 1.5 psi such
that the assembly's internal air pressure is less than the
Maintain the pressure differential for a two
external pressure.
After exposure,
minute period.  Verify that there is no leakage.
subject the assembly to the performance tests of 4.6.1.
Subject the assembly in its
4.6.3.2  High  temperature.
normal operating condition to the high temperature test specified
in MIL-STD-810, Method 501, except storage temperature shall be
for 48 hours.
At the conclusion of the storage temperature
test, stabilize the assembly at
and subject it to the
After testing,
performance tests of 4.6.1.1.1 through 4.6.1.1.5.
return the assembly to room temperature and subject the assembly
to the performance tests of 4.6.1.
Subject the assembly in its normal
4.6.3.3  Low  temperature.
operating condition to the low temperature test specified in
for a
MIL-STD-810, Method 502.  Maintain the temperature at
At the conclusion of the storage
period of 12 hours minimum.
and subject it
temperature test, stabilize the assembly at
After
to the performance tests of 4.6.1.1.1 through 4.6.1.1.5.
12

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business