| MIL-T-48558B(AR)
TABLE I. Requirements
and
test
Procedures.
(cont.)
No.
Characteristic
Requirement
Test
procedure
112.
Image tilt
4.8.9
3.10.5
113.
Collimations - Reticle
4.8.2
3.11.1
114.
Operability - Torque
3.12.1
4.8.10
115.
4.8.10
Attachment
3.12.2
Locating & Locking Mechanism
116.
4.8.10
3.12.2.1
117.
Reticle
Illumination
3.13.1
4.8.11
118.
Radiological Contamination
3.6.6
4.8.12
119.
Fabrication
11741626
3.4
Workmanship
120.
MIL-O-13830 &
3.15
MIL-F-13926
121.
Packaging
5.1
4.10
Minor:
None
4.4 Special
sampling.
4.4.1 General. Subsequent to meeting the requirements of
Table I, three telescopes shall be selected at random by a
Government representative as a special sample from each 50
produced or from each month's production, whichever occurs first.
The samples shall meet the requirements and tests in Table I
after being subjected to Table II testing.
TABLE
II
NO.
CHARACTERISTIC
REQUIREMENT
TEST
PROCEDURE
301.
Storage temperature
4.7.1
3.7.1
302.
Operating
temperature
3.7.2
4.7.1
303.
Operability
3.12
4.8.10
4.4.2 Failure of sample. Should any one item of a special
sampling fail to meet the specified test requirements, acceptance
of the represented inspection lot will be suspended by the
Government until necessary corrections have been made by the
contractor and the resubmitted samples have been approved.
4.5 Test
equipment.
4.5.1 Inspection
equipment. Except as otherwise provided
for by the contract, the contractor shall supply and maintain
inspection equipment in accordance with the applicable
requirements of MIL-I-45607.
10
|