| MIL-T-50713A
202 Box damaged Visual
203 Marking missing, incorrect, or illegible
Visual
204 Cut, damaged, or improperly sealed bag
Visual
4.3.2.17 Box, Packing, Ammunition, Drawing 8797742.
Critical
None defined
Major
None defined
Minor
201 Contents loose Visual/Manual
202 Strapping missing, loose, broken, or improperly assembled
Visual/Manual
203 Contents of box exposed Visual
204 Box damaged Visual
205 Marking missing, incorrect, or illegible
Visual
206 Number of units incorrect Visual
4.3.2.18 Box, Fiberboard (Outer), Alternative, Packing, Ammunition, Drawing 9217579.
Critical
None defined
Major
None defined
Minor
201 Contents loose Manual/Visual
202 Hardware missing, loose, broken, or improperly engaged
Visual
203 Strapping missing, loosed, broken, or improperly engaged
Visual
204 Contents of box exposed Visual
205 Box damaged Visual
206 Marking missing, incorrect, or illegible
Visual
4.4 Inspection testing. The following tests shall be performed in accordance with 4.5.
4.4.1 Hydrostatic pressure. Each body and head shall be subjected to the hydrostatic pressure
test. Failure of any unit to comply with 3.2 shall be cause for rejection of the subassembly.
4.4.2 Structural strength. Each thruster shall be subjected to the structural strength test.
Failure of any thruster to comply with the requirements of 3.3 shall be cause for rejection of the
thruster.
11
|