MIL-T-52932D
failure during the conduct of the demonstration and test is required. As a
minimum, the report shall describe components and parts affected, rest and
g conditions, date of incident, hourmeter reading, how detected and
description of incident and corrective action taken. A minimum Of one
original will be furnished the pertinent contracting officer specified in the
contract.  Distribution of copies will be identified in the contract.
6.5 Definitions.
6.5.1 Campacity load.  Capacity load shall be established with a load
equivalent to an unrestrained cube with overall dimensions twice the load
center dimensions and whose center of gravity is located at the geometrical
center of the cube.  The tolerances for weight shall be 1 percent and -0
percent.
6.5.2 Load center.  The load center shall be defined as the horizontal
longitudinal distance from the intersection of the horizontal load carrying
surfaces and vertical load-engaging faces of the forks to the center of
gravity of the load.  The tolerances for dimensions shall be 1 percent
6.6 Noise levels;  When the required maximum noise limit(s) are established
to be technically infeasible and beyond the state-of-the-art for the item/
system being procured, the contracting officer may request additional
information on noise sources.  As such, documentation shall be furnished to
the procuring activity for consideration of whether or not increase of the
required limit(s) is justified and how noise levels may best be minimized.
Documentation shall contain technically defensible data including technically
supported design considerations, technically supported design recommendations
for noise reduction, and technically supported predictions of the resultant
noise levels.  Clearly stated, convincing, and techically/fiscally supported
trade-off analyses of noise control benefit against other design requirements
such as weight, access, etc., shall be provided.
6.7  Conditional for use of level B preservation.  When level B preservation
is specified (see 5.1), this level of protection should be reserved for the
acquisition of trucks for resupply worldwide under known favorable handling,
transportation, and storage conditions.
6.8 Disposability.  One or more of the following methods shall be used to
accomplish disposal of lubricating oils, antifreeze, batteries, paint and
tires; reuse, recycling, baling, sanitary landfill, comporting, incineration,
pyrolysis, or sea disposal.
6.9 Government-loaned property.  The contracting officer should arrange to
loan the property listed in 3.8.1.