| MIL-T-60201C
4.2.2 Examination. One hundred percent examination shall be performed for all critical
defects. Examination for major and minor defects shall be performed in accordance with the
classification of defects. Four power (4x) magnification may be used for inspection of such
defects as burr and foreign matter. When compliance with the applicable requirement is in doubt
as a result of visual examination, the characteristic shall be measured or gaged to determine
acceptability. All nonconforming material shall be rejected.
4.2.2.1 Cartridge, Drawing 10520589, covering a detail of Drawing 11730533.
Characteristics
Defect
Method of Inspection
Critical
1
Mixed cartridges
Visual
2
Metal defective
Visual
3
Marking missing, incorrect, or illegible
Visual
Major
101 Foreign matter present
Visual
Minor
201 Case scratched or dentedVisual
4.2.2.2 Retainer, Guide Subassembly, consisting of Guide Retainer and Pellet Assembly
10521616, Shear Pin 10521618, Firing Pin 8593864, and O-Ring MS29513-12, covering a detail of
Drawing 11730533.
Critical
1
Striker hole obstructed
Visual
Major
101 Foreign matter Visual
Minor
None defined