4.2 Inspection conditions. Unless otherwise specified (see 6.2), all inspections shall be performed under
the following conditions:
a.
Temperature: room ambient (68 to 77F)
b.
Altitude: sea level
c.
Humidity: 50 percent relative, maximum
d.
Atmospheric pressure: 14.7 psi
4.3 Quality conformance inspection.
4.3.1 Lot.
4.3.1.1 Submission of product. Unless otherwise specified by the contracting activity, formation and
identification of lots shall be in accordance with MIL-STD-105.
4.3.1.2 Size of lot. For the purpose of identification and shipment, the shipping lots of metal parts
assemblies shall consist of 1200 assemblies, maximum, provided the homogeneity requirements of inspection
lots have been retained.
4.3.2 Examination. On reprocessed parts, one hundred percent examination shall be performed for all
critical defects. Examination for major and minor defects shall be performed on a defect basis in accordance
with the classification of defects. Four power (4x) magnification may be used in performing visual
examination for such defects as burr and foreign matter. Inspection for rubber O-rings shall be in accordance
with MIL-STD-413. When compliance with the applicable requirement is in doubt as a result of visual
examination, the characteristic shall be measured or gaged to determine acceptability. All nonconforming
material shall be rejected.
4.3.2.1 Examination of reclaimed parts. Examination of reusable parts, which require no reprocessing,
shall be limited to inspection of defects that require visual type inspection. One hundred percent examination
shall be performed for all such defects. All nonconforming parts shall be reprocessed or rejected.
4.3.2.2 Pin, Firing, Drawing 8593878, covering a detail of Drawing 10520876.
Characteristics
Defect
Method of Inspection
Critical
None defined
Major
101
Metal defective
Visual
102
Protective finish inadequate or defective
Visual
103
Burr or sharp corner
Visual
104
Foreign matter
Visual
Minor
5