| MIL-T-60826B(MU)
The tests of Table I shall be conducted at a temperature
NOTE:
between +60 and +90F.
4.3.3 Acceptance and rejection. - Rejected lots shall be screened
for all defective characteristics. Removal or correction of defective
units and resubmittance of rejected lots shall be in accordance with
"Acceptance and Rejection" as specified in MIL-STD-105.
4.4 Special sampling.
4.4.1 General. - One telescope shall be selected at random as a
special sampling from each 100 produced. The sample shall meet the
requirements and tests in Table II.
4.4.2 Environmental. - Three telescopes shall be selected at random
as samples form each 50 produced, or from each month's production, which-
ever occurs first. Each sample shall meet the requirements and tests
of Table III.
The tests for Characterisitics 304 through 311 inliclusive shall
NOTE:
be conducted at -65 and +150F.
4.4.3 Failure of sample. - Should any one item of a special sampling
fail to meet the specified test requirements, acceptance of the product
shall be suspended by the Government until necessary corrections have
been made by the contractor and resubmitted samples have been approved
(see 4.3.3).