4.5 Quality conformance inspection.
4.5.1 Sampling. Each turret trainer produced (100 percent) shall be subjected to examination
(see 4.5.2) and acceptance tests (see 4.5.3).
4.5.2 Quality conformance examination.
4.5.2.1 Acceptable quality level. Each turret trainer shall be examined for conformance to
following acceptable quality levels (AQL's) on the basis of percent defective:
Classification
AQL
Major
0.25
Minor
1.50
4.5.2.2 Classification of defects. For examination purposes, defects shall be classified
according to MIL-STD-105, and as follows:
TABLE V. Classification of defects.
Categories
Defects
Method
Major:
101
Dimensions affecting interchangeability not within
Visual/SIE 1/
tolerance (see 3.3. and 3.3.3).
102
Visual/SIE
Mountings missing, improper, broken, bent
(see 3.3.3, 3.3.3.1).
Visual/SIE
103
Level sensors missing, improperly installed,
broken (see 3.3.3.2).
Visual/SIE
104
Electrical junction box incomplete, improper
electrical properties, improper ground
(see 3.3.3.3).
Visual
105
Power cable missing, incomplete, exposed
conductor, improper insulation (see 3.3.3.4).
Visual/SIE
106
Turret improperly installed, inoperable (see 3.3.4).
Visual/SIE
107
Missile launcher improperly installed, inoperable
(see 3.3.5).
Visual/SIE
108
Missile launcher mounting kit improperly installed
(see 3.3.6).
Visual/SIE
109
Squad leader's periscope improperly installed,
inoperable (see 3.3.7).
Visual/SIE
110
M26 periscope improperly installed, inoperable
(see 3.3.8).
16
|