Click here to make tpub.com your Home Page

Page Title: Hydraulic system
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-T-62497
than 2.0 times the maximum operating load. For ease of service, hydraulic valve assembly,
including relief valve, shall be located so that it will be accessible at all times and under all load
conditions.
3.5.6.1 Hydraulic system. Relief valves shall be provided in the hydraulic system to
prevent excessive hydraulic pressure and shall be set to relieve hydraulic pressures in excess of
that recommended by the manufacturer. A hydraulic T-fitting, or equivalent, for insertion of a
pressure gage, shall be provided in the line beyond the main relief valve to facilitate checking the
line pressure. All circulating fluid shall pass through a full-flow hydraulic fluid-filter. The filter
element mesh shall be of a size to limit circulation of particles of 10-micron size or larger. The
filter shall be located so that it will not contribute to pump cavitation and shall be accessible for
servicing. Hydraulic lines, hoses, and fittings shall meet or exceed the requirements of
Recommended Practices and Standards contained in the SAE Handbook. A reservoir shall be
provided with sufficient flow volume to maintain the fluid temperature below the recommended
limits and shall incorporate an oil level indicator. All valving shall be equipped to be stopped or
reversed at any time during operation.
3.5.6.1.1 Hydraulic cylinders. All exposed hydraulic cylinders shall be fitted with seals to
prevent entrance of dirt, moisture, and other foreign elements and to preclude leakage of
hydraulic fluid. The exposed portions of hydraulic ram piston rods shall be chrome plated with
sufficient thickness to withstand a 30-hour salt spray test in accordance with ASTM Designation
B-117. The connecting ends shall be treated in the best commercial practice.
3.5.6.1.2 Hydraulic fluid. Unless otherwise specified, hydraulic fluid conforming to the
manufacturer's standard or recommended requirements shall be provided in the hydraulic system.
A corrosion-resistant plate indicating the type of hydraulic fluid to be used shall be installed near
the filler cap. When specified (see 6.2), hydraulic fluid conforming to MIL-H-83282 shall be
provided in the hydraulic system. A permanent decal located near the hydraulic system fill port
shall be furnished stating "CAUTION: USE HYDRAULIC FLUID CONFORMING TO
MIL-H-83282 ONLY."
3.5.6.2 Controls. Controls for the container lift, the packing mechanisms, and for refuse
ejection or dumping shall be located in the right hand drive area of the cab. The controls shall be
of the interrupted cycle or deadman type. Lift controls shall be lever actuated hydraulic. The
speed of the engine shall be controlled automatically for proper operation of the body hydraulic
system. A neutral interlock shall be installed to prevent advancing the throttle from the lift and
ejection or dumping controls unless the vehicle automatic transmission is in neutral.
17

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business