| MIL-T-63534(AR)
TABLE I. Major component list
Ref
Des
Component
Drawing Number
-
189F81 9
Case, Electrical Equipment
189F960
Component Assembly, Demodulator,
Al
Power Supply
11830909
Component Assembly, Filter, Limit
A2
Switch
11830800
Component Assembly, Current Loop
A3
&
A4
J 1830799
A5
Component Assembly, Interconnection
139C7957
Component Assembly, Driver
132D1354
A8
Component Assembly
3.1.2 Power supply. The TCU Shall meet the requirementS Of MIL-STD-704.
During normal operation of the primary electrical system, the TCU shall meet
the requirements of Paragraph 5.3.2 of MIL-STD-704. During abnormal operation
of the electrical system, the TCU shall meet the requirements of Paragraph
5.303 of MIL-STD-704. The power supply for all acceptance tests shall be As
specified in Table II.
Table II. Electrical Power
Pin
Power Form
Nominal
Peak
1.0 ampere
28 Vdc Low Level
J2-G
2 amperes
J2-E
Return for J2-G
10 amperes
E1
28 Vdc High Level
200 amperes
E2
Return for El
115 v, 400 Hz, 1 0
70 volt-amperes
95 volt-amperes
J2-H
Return for J2-H
J2-J
1 volt-ampere
26 V, 400 Hz, 1 0
2 volt-amperes
J2-L
J2-K
Return fOr J2-L