| ![]() MIL-T-63534(AR)
3.8.4 Humidity. The TCU shall withstand the effects of humidity up to
100 percent,including conditions wherein condensation takes place in and on
the TCU. The TCU shall withstand the above conditions during operating and
non-operating conditions.
3.8.5 Vibration. The TCU shall meet the requirements of MIL-E-5400,
paragraph 3.2.24.5.1.3 except as modified by drawing.
3.8.6 Shock. The TCU shall meet the requirements of MIL-E-5400,
paragraph 3.2.24.6.
3.8.7 Sand and dust. The TCU shall withstand, in both an operating and
non-operating condition, exposure to sand and dust particles as encountered in
areas of the world.
3.8.8 Fungus. The TCU shall withstand, in both an operating and
non-operating condition exposure to fungus growth as encountered in tropical
climates.
3.8.9 Salt fog. The TCU shall withstand, in both an operating and
non-operating condition, exposure to salt-sea atmospheres.
3.9 Workmanship. Workmanship and finish shall be in accordance with
Mil-STD-434, Requirement 9. Finished items and parts shall not exhibit faulty
material and processing such as seams, laps, laminations, cracks, visible
steps, sharp edges, nicks, scratches, burrs, foreign matter, deformations, and
missing operations which may affect serviceability, operation, or safety.
4. QUALITY ASSURANCE PROVISIONS
4.1 Responsibility for inspection and standard quality assurance
provisions. Unless otherwise specified herein or in the contract, the
provisions of MIL-W-63150 shall apply and are hereby made a part of this
detail specification.
4.1.1 Certification provisions. The certification provisions of
MIL-W-63150 shall apply.
4.2 Quality assurance terms and definitions. Quality assurance terms and
definitions used herein are In accordance with MIL-STD-109.
4.3 Classification of inspections. The following types of inspection
shall be conducted on this item:
a. First article inspection.
b. Quality conformance inspection.
17
|