  | ![]() MIL-T-63536(AR) 
3.4 Interchangeability. All parts having the same part number shall be 
completely interchangeable with each other and with like parts of other 
manufacture with respect to installation and performance. Parts joined 
together by welding, brazing or riveting shall be interchangeable as 
assemblies. Interchangeability shall be in accordance with MIL-STD-454, 
Requirement 7. 
3.5 First article inspection. This specification contains technical 
provision for first article inspection. Requirements for the submission of 
first article by the contractor shall be as specified in the contract ancf 4.4. 
3.6 Characteristics. 
3.6.1 Performance. The LCU shall comply with the performance 
requirements specified herin, when tested as specified in 4.5, 4.6 and 4.7. 
3.6.1.1 Electronic characteristics. The LCU electronic characteristics 
shall be as specified in Table III. 
TABLE III. Electronic characteristics. 
Characteristics 
Connector 
Function 
Voltage 
Current 
Pin 
Differential amplifier, A5AR1, 
0-10 Vac 
Gunner Q-Signal 
J1-A 
inverting input via relay 
400 Hz 
Input 
contacts and 348 kilohms. 
Return 
Return 
Gunner Q-Signal 
JI-B 
See J1-A 
Return 
Chassis Ground 
J1-C 
Into a minimum load of 200 
0-3 Vac 
Elevation Servo 
J1-D 
400 Hz 
kilohms. 
Error Output 
Low level return 
Return 
Elevation Servo 
J1-E 
Error Return 
Low level return 
Return 
Yaw Output 
J1-F 
Voltage Return 
Current into a single ended 
O to +3 Vdc 
Azimuth Demod 
JI-G 
inverting amplifier through 
Input 
a 10 kilohms resistance. 
O to +3 Vdc 
Same as J1-G 
Elevation Demod 
J1-H 
Input 
5 
 | 
| 
 