| ![]() MIL-T-63536(AR)
TABLE III. Electronic characteristics (continued)
Connector
Function
Characteristics
Pin
J3-A(1)
+15 Vdc Test Point
Direct connection to +15 Vdc internal power
supply.
Direct connection to -15 Vdc internal power
J3-B
-15 Vdc Test Point
supply.
Chassis Ground
J3-C
+15 Vdc through 10K in normal mode, -15 Vdc
Depression Limit
J3-D
through 20 kilohms when in depression limit
Condition Signal
with J1-j at 1.0 Vac in phase with J2-U.
Voltage same as voltage on J1-A when
J3-E
Selected Control
Mode (Gunner,
J2-A, B, and C = 0 Vdc
Pilot, TSU)
Test Point
Voltage same as voltage on J1-T when J2-B
or C = 28 Vdc
Voltage same as voltage on J1-c when J2-A =
28 Vdc and both J2-B and C = O Vdc
Ground Circuit
Continuity through wire to J2-n and J1 -R
J3-J
Closure, Gun
Power Relay
Voltage across DS1 0.0 0.5 Vdc = unlit
J3-K
900 Error
1.60.5 Vdc = lit
Detector Voltage
Parallel with J2-b
J3-L
Gunner Stow
Interupt Test
Point
Direct connection to +5 Vdc internal power
J3-P
5 Vdc Test Point
supply
Parallel with J1-D
Depression Limit
J3-R
Output to Test Set
Note 1. J3 is a test connector for system checkout with a test set.