  | ![]() MIL-T-63536(AR) 
TABLE III. Electronic characteristics (continued) 
Connector 
Function 
Characteristics 
Pin 
J3-A(1) 
+15 Vdc Test Point 
Direct connection to +15 Vdc internal power 
supply. 
Direct connection to -15 Vdc internal power 
J3-B 
-15 Vdc Test Point 
supply. 
Chassis Ground 
J3-C 
+15 Vdc through 10K in normal mode, -15 Vdc 
Depression Limit 
J3-D 
through 20 kilohms when in depression limit 
Condition Signal 
with J1-j at 1.0 Vac in phase with J2-U. 
Voltage same as voltage on J1-A when 
J3-E 
Selected Control 
Mode (Gunner, 
J2-A, B, and C = 0 Vdc 
Pilot, TSU) 
Test Point 
Voltage same as voltage on J1-T when J2-B 
or C = 28 Vdc 
Voltage same as voltage on J1-c when J2-A = 
28 Vdc and both J2-B and C = O Vdc 
Ground Circuit 
Continuity through wire to J2-n and J1 -R 
J3-J 
Closure, Gun 
Power Relay 
Voltage across DS1 0.0  0.5 Vdc = unlit 
J3-K 
900 Error 
1.60.5 Vdc = lit 
Detector Voltage 
Parallel with J2-b 
J3-L 
Gunner Stow 
Interupt Test 
Point 
Direct connection to +5 Vdc internal power 
J3-P 
5 Vdc Test Point 
supply 
Parallel with J1-D 
Depression Limit 
J3-R 
Output to Test Set 
Note 1. J3 is a test connector for system checkout with a test set. 
10 
 | 
| 
 
 Privacy Statement - Press Release - Copyright Information. - Contact Us  |