Page Title: Output for azimuth error detector
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-T-63536(AR)
3.6.1 .4.3.1 Output for azimuth error detector. With the initial
conditions of 3.6.1.4.3 plus the inputs given below, the outputs shall be:
Input
Output
28 (0.5, -O) Vdc at Pin J2-j,
20 Vdc (15%) at PinJ1-L
and 5 V rms (5%) at Pin J1-j,
1800 out of phase with the
26 Vac applied at Pin J2-U,
with return to Pin J1-f
Voltage at Pin J1-L changes
A positive or negative
from 20 Vdc (15%) to
polarity d-c voltage at Pin J1-G
which is increased in level from zero
0(0.4) Vdc
until J1-L changes to a O Vdc level.
The voltage on J1-G shall be between
222 to 445 mVdc with either of the
polarity applied to J1-G
3.6.1.4.3.2 Output of J1-L.  The output of J1-L shall be O (+ 4) Vdc when
the inputs of 3.6.1 .4.3 occur and if any one or more of the following
conditions occur:
a. 0 Vdc on J1-G, 28 Vdc on J2-j, and 1 Vac on J1-j in phase with
J2-U
b. 0 Vdc on J2-D
c. 0 Vdc on J2-E
d. 0 Vac on J1-A
e. 0 Vdc on J2-b.
3.6.1.4.4 One and one-half degree elevation error detector. With input
power as specified in 3.1.3 and O Vdc (0.200) on J1-H, the output at J1-H
shall be 28 (1.0) Vdc (open circuit, i.e., no load at J1-H). When J1-H input
is increased in either dc polarity, the output at J1-M shall change from 28
Vdc to O (0.4) Vdc prior to a maximum of 445 millivolts dc.
3.6.1.5 Coincidence sensor component assembly. With the inputs as
specified below, the events described in the following subparagraphs shall
occur.