| MIL-T-81290(WP)
c. Parallel to the minor horizontal axis, 3 shocks in each direc-
tion.
The Test Set shall not suffer damage or subsequently fail to meet the per-
formance and product characteristics of the specification.
4.4.9 Vibration. Subject the Test Set to vibration tests for Type 1
equipment as specified in Standard MIL-STD-167 up to 33 CPS. The Test Set
shall meet all operational requirements herein while subjected to this
environment.
4.5 Cause for Rejection. Failure of the Missile Test Set to meet any
of the requirements of this specification shall be considered cause for re-
jection.
PREPARATION FOR DELIVERY
5.
5.1 Preservation and Packaging
5.1.1 Level A. (See 6.4)
5.1.1.1 Cleaning. The Test Set shall be cleaned as specified in
Specification MIL-P-116, Method C-1.
5.1.1.2 Drying. The Test Set shall be dried as specified in Spec-
ification MIL-P-116, Method D-4.
5.1.1.3 Unit Packaging. The Test Set shall be individually packaged
as specified in Specification MIL-P-116, Method IC-2.
5.1.2 Level C. (See 6.4) Cleaning, drying, preservation and packaging,
s
shall be in accordance with the supplier commercial practice, when such
practices have been proven by testing to conform to all applicable require-
ments.
5.2 Packing
5.2.1 Level A (See 6.4) One unit package of the Test Set, shall be
packed in a nailed wood box conforming to the requirements of Specification
PPP-B-621, Class 2, Type 1 and 2 load. The container shall be strapped in
accordance with instructions contained in the appendix of the above spec-
ification. The pack shall protect the Test Set within the shock require-
ments of this specification when subjected to the Rough Handling Test of
MIL-P-116.
5.2.2 Level C. One or more unit packages shall be packed in accordance
with supplier's commercial practice. The pack shall protect the Test Set
within the shock requirements of this specification when subjected to the
Rough Handling Test of MIL-P-116.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |