3.4.1.5 Primar y Input power Requirements.
The equipment shall require
power of the following type and shall not exceed the specified amounts.
AC Power: 3-phase$ 115/200V + 5 percent, 380 to 420 Hz,
85 Amperes (A)/Phase
DC Power: 27 + 2 Vdc, 70 A
3.4.1.6 Contents of Unit.
The Table -Rack shall consist of the following
major units:
(a) Support Assembly, RF Section
(b) Bench Assembly, Pallet Section
(c)  Test and Contro1 Rack
(d) Indicator Bench
(e) Computer Bench
(f)
Hydraulic Supply
Liquid Cooling System
(g)
(h) Test Accessories
(i)  Antenna Support Fixture
Interconnecting Test Harness
(j)
(k) System Harness
3.4.1.6.1 Support Assembly, RF Section.
3.4.1.6.1.1 Function. The RF Section Support Assembly shall mount the
RF Section of the AN/APG-59 Radar Set and shall make it accessible for use
in the fault isolation, adjustment and repair or replacement of defective
circuits, plug-in assemblies, and components of the RF Transmitter
Assembly.