MIL-T-81527B(AS)
3.4.1.6.4.2.1.3 Convenience Power Outlets. Four Duplex Convenience
Power Outlets rated at 115 Vat, 25A shall be provided at the rear of the
structure above the Bench Top,
These Outlets shall receive their power
from the convenience power outlet terminal strip installed on the underside
of the center section of the upper shelf, The Outlets shall be 2-pole, 3-wire,
shall be polarized and shall meet the requirements of MIL-C-3767, The
terminal strip shall be connected directly to the Primary ac Power Source
by the using facility and shall not be connected through the Circuit Breakers.
3.4.1.6.4.2.2 Radar Indicator Support Structure.
3.4.1.6.4.2.2. 1 Function.  This structure shall support the Radar Indicator
s o that it can be viewed easily from several angles and can be rotated and
raised for each maintenance.
The normal mounting points of the Radar In-
3.4.1.6.4.2.2 Form Factor.
dicator shall be used, and the Structure shall incorporate a turntable capable
of rotating and locking the Radar Indicator at any angular position within
+ 90 degrees + 5 degrees in the horizontal plane.  The Structure shall be cap-
able of lifting and locking the Radar Indicator at 30 degrees elevation and
also to be slid forward and locked in the vertical position to provide
The weight of this structure shall not
access to the bottom of the indicator.
exceed 38 pounds.
3.4.1. 6.4. 2.3 Command Indicator Support Structure.
3.4.1. 6. 4.2.3.1 Function.
The Command Indicator Support Structure shall
support the Command Indicator and shall make it accessible for repair.
3.4.1.6.4.2.3.2 Form Factor.
The normal mounting points of the Com-
mand Indicator shall be utilized.
The structure shall be capable of being
lifted and locked at 30 degrees in the vertical plane. The structure shall
also have slide rails to permit the Command Indicator being slid to the front
of the Indicator Test Bench and then to be lifted and locked at 90 degrees
elevation and also to be slid forward and locked in the vertical position to
provide access to the bottom of the indicator. The weight of the support
structure shall not exceed 14 pounds.
43