| MIL-T-81527B(AS)
The harness shall provide for connecting the Wave guide
and Control Rack.
Switch coil voltage from the dummy jack to the Test and Control Rack
(3.4.1.6.8.9.2).
3.4.1.6.10.2 Form Factor.
The Inter connecting Test Harness shall extend
the length of the Table-Rack and shall interconnect the line Replaceable
Unit (LRU`s) of the AN/APG-59 Radar Set located throughout the several
units of the table-rack listed in 3.4. 1 except those LRU's which are normally
installed on the Barrel Assembly of the AN/APG-59 Radar Set. The Inter-
connecting Cable Harness shall connect directly to the System Cable Harness
at the Interconnecting Test Harriess Shelf to provide an interface with the.
AN/APG-59 Barren Assembly LRU'S installed on the RF Section Support
Assembly and the Reciever Section Bench Assembly.
t
3.4.1.6.10.3 Connectors.
Connections to the AN/APG-59 Radar Set LRU s
shall be made with approved connectors:
Reference Designation
Function
8P1
Power Supply (PP-4451/APG-59)
8
8P2*
Power Supply (PP-4451/APG-59)
9P1*6
Command Indicator
9P2
Command Indicator
2
10P1*
Radar Indicator
1OP2
Radar Indicator
6
llPl*
Indicator Control
6
11P2*
Indicator Control
11P3
Indicator Control
11P4
Indicator Control
15P1
Velocity Signal Computer
15P2
Velocity Signal Computer
Velocity Signal Computer
15P3
*2 See paragraph 6.5.2
*6 See paragraph 6.5.6
*8 See paragraph 6.5.8