| MIL-T-81776C(AS)
The MTS shall provide the following interfaces.
3.2.1.12 Interface.
3.2.1.12.1 Clean air interface. The MTS shall interface with clean
air through ducts entering the top rear of each bay.
3.2.1.12.2 Electrical power interface. The MTS shall interface with
electrical power for the convenience outlets at one end of the convenience
outlet strip mounted on the top of the front face of the MTS, The MT'S
shall interface with all other electrical power through power lines
entering the top of bay number 2.
3.2.1.12.3 MATS/MITS interface. The MTS shall interface with the MATS
using the MATS adapter (3.6.3.3) and the cable set of MIL-C-81954(AS).
The MTS shall interface with the MITS using the MITS adapter (3.6.3.4) and
the cable set of MIL-C-81954(AS).
3.2.2 Utilities.
Applicable.
3.2.2.1 Electrical power. Applicable. Electrical power required for
operation of the MTS shall be as listed in Table II.
3.2.2.2 Clean air.
Applicable, except that clean air shall not exceed
33 pounds per minute.
Not applicable.
3.2.2.3 Potable water.
3.2.2.4 Liquid coolant.
Not applicable.
3.2.2.5 Helium.
Not applicable.
3.2.2.6 Nitrogen.
Not applicable.
3.2.2.7
Hydraulic fluid.
Not applicable.
TABLE II
MTS ELECTRICAL POWER FORMS
Item
Input Power Form
Maximum Load
1
+29
Vdc
0.05 kilowatt (KW)
2
115 Vac, 400 Hertz (Hz) 3-phase,
1.0 kilovolt-amperes
4-wire, Type III
(kVA)
3
1.75 kVA
115 Vac, 60 Hz, 1-phase, Type 1
4
115 Vac, 60 Hz, 3-phase, 3-wire,
2.0 kVA
ungrounded, Type I
-5-
|