|
| MIL-T-81776C(AS)
3.6.2.7 Programmable pulse generator. A programmable pulse generator
Chronetics 1012-1, or equivalent, shall be supplied and shall include the
performance characteristics specified in 3.4.1-.2.2. The pulse generator
shall be a highly versatile source of voltage pulses. Separate control
of repetition rate, pulse width, pulse amplitude, rise time, fall time,
and dc offset shall be provided. The instrument shall have the capability
of being remotely programmed as well as being operated by front panel con-
trols. In addition, the instrument shall be capable of providing a burst
of pulses gated by an external signal.
5.6.2.8 Drawer assembly, storage, tool and tape. The tool and tape
storage drawer assembly shall provide storage for special tools and pro-
gram tape reels as specified in 3.2.l.9.1. Dimensions shall be 16 inches
by 24 inches by 10 inches.
3.6.2.9 Distribution Box J-3111( )/AWM-23(V). The distribution box shall
provide connectors for the correct voltage and phase distribution of the_
three phase, 60 Hertz primary input power to the test equipment utilized in
the test station.
3.6.3 Adapters. The MTS, OJ-217( )/AWM-23(V) shall include 80 adapters
(see 6.9).
and the MTS, 03-378( )/AWM-23(\T) shall include 70 adapters.
The module adapters shall conform to the following
3.6.3.1 Module.
requirements :
Size - 1.75 x 6.0 x 8.12 or 1.75 x 6.0 x 6.12 inches
Weight -Not to exceed three pounds each.
3.6.3.2 Self test.
The self test adapter shall conform to the following
requirements :
a.
Size - 1.75 x 6.0 x 8.12 inches
Weight - Not to exceed three pounds.
b.
3.6.3.3 Missile Auxiliaries Test Set. The Missile Auxiliaries Test Set
adapter shall conform to the following requirements:
a.
Size - 18 x 11 x 6 inches, maximum
Weight - Not to exceed 25 pounds.
b.
3.6.3.4 Missile Interface Test Set. The Missile Interface Test Set
adapter shall conform to the following requirements:
Size - 18 x 12 x 12 inches, maximum
Weight - Not to exceed 35 pounds.
3.6.4 Elapsed time meter. An elapsed time meter, conforming to MIL-M-
7793, shall be provided. The meter shall be readily visible during opera-
tion of the MTS, and shall be capable of registering at least 9,999 hours.
-17-
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |