MIL-T-81782C(AS)
Applicable.
3.2.1.2 Commercial test equipment.
Other commercial components.
3.2.1.2.1
Applicable.
Applicable.
3.2.1.3 Circuit grounds.
3.2.1.4 Interchangeability.
Applicable.
Applicable.
3.2.1.5 Identification of product.
Applicable.
3.2.1.6 Human factors.
Applicable.
3.2.1.7 Test set generated acoustic noise.
3.2.1.8 Forced-liquid cooling.
Not applicable.
Space and weight limitations. The weight of the CTS shall be
3.2.1.9
less than
4000 pounds.  Maximum dimensions shall be 96 inches by 36.25
inches by
75 inches with all drawers and retractable work surfaces in the
retracted
position.
3.2.1.9.1 Storage space.  Storage space shall be provided in two locations
in computer bay no. 4.  One storage area shall be located to the right of
Control, Logic, Magnetic Tape Reader C-9182( )/AWM-23(V) immediately above
the work surface, and shall be used to stow any simulator or the slave digi-
tal computer weapon replaceable assembly (WRA) when it is removed.  The
other storage area shall be provided within the drawer located below the
retractable work surface. This storage area shall be used for stowage of
test leads and magnetic tape reels and will provide some space for manuals.
In addition, a minimum of three cubic feet of separate storage facilities
will be required to store miscellaneous equipment.
3.2.1.10 Connectors.
Applicable.
3.2.1.11 Secondary electrical power.  The total secondary electrical
power shall be limited to 1900 watts maximum with any combination of power
form loading within the load capability limits for each power form listed
in Table I.  Secondary electrical power shall consist of regulated power
forms.  Regulation from no load to full load, and for normal values of
facility line voltage variations shall not exceed 2 percent at the voltage
sense point.  Ripple voltage for dc power forms shall not exceed 150 milli-
volts (mV) peak-to-peak (p-p).
3.2.1.12 Interface.
Applicable.
3.2.1.12.1 Clean air interface.  The CTS shall interface with the clean
air through ducts which enter the CTS at the top rear of each test console.
3.2.1.12.2 Electrical power Interface. The CTS shall interface with
electrical power for the convenience outlets at one end of the convenience
outlet strip mounted on the top of the front face of the CTS. The CTS
shall interface with all other electrical power through power lines enter-
ing the top of bay number 4.
-4-