| MIL-T-81785C(AS)
3.2.2.6 Nitrogen.
Applicable.
Not applicable.
3.2.2.7 Hydraulic fluid.
3.2.3 Service conditions.
Applicable.
3.2.3.1 Electrical.
2.3.2 Environmental.
Applicable.
3.2.3.2.1 Organizational level.
Not applicable.
3.2.3.2.2
Intermediate level.
Applicable.
3.2.4 Maintainability.
Applicable.
3.2.4.1 Mean time to repair.
Applicable.
3.2.4.2 Test points. Applicable. Test points shall be provided to facili-
tate fault isolation to the shop replaceable assembly (SRA) level, fault
isolation within an SRA, alignments or adjustments, calibration, and signal
monitoring.
Applicable.
3.2.4.3 Shop replaceable assemblies-
3.2.4.4 Self test capability. In the event of self test failure, the RFTS
shall provide capability to establish its functional readiness. Time for self
test shall not exceed 30 minutes. The RFTS shall provide capability to isolate
faults to:
Commercial test equipment (CTE) item.
SRA level for panel and drawer assemblies.
3.2.5 Reliability.
The mean time between failures shall be 60 hours mini-
mum.
Operating life.
Applicable.
3.2.5.1
Storage life.
Applicable.
3.2.5.2
3.2.5.3
Applicable.
Operational stability.
Applicable with the following
3.2.6 Electromagnetic interference (EMI).
exceptions:
MIL-STD-461, test CE03 limits for the 115/200 Vat, 400 Hz leads
a.
shall be 40 dB above the limits specified in Figures 14 and 15
of MIL-STD-461.
MIL-STD-461, test RS02 shall not apply to the 115/200 Vat,
b.
400 Hz leads.
MIL-STD-461, tests CE03 and RS02-1 and the limits therein shall
c.
apply unless otherwise specified above.
-7-
|