| ![]() Terminations
3.7.1.2
MS3106E28-21S
W5P1
Kern Engineering CT0699 with Amphenol
W5P2
insert 115-1388
Alden Products #6102 UL51
W5P3
MS3106E32-2O1O-1OP
W12Pl
MS3106E32-2O1O-1OS
W12P2
MS3106E32-2O1O-1OSW
W13Pl
Amphenol 67-06E22-48P
W13P2
Shielding - The cables shall be shielded such that no RF pickup
3.7.1.3
shall be conducted into the Fire Control System Test Set circuitry.
Cable Set Container - The cable set shall include a combination
3.7.1.4
case for their storage. The overall dimensions of this container shall not exceed 14 inches
wide by 14 inches high by 21 inches long.
Weight - The total weight of cable set and container shall not
3.7.1.5
exceed 45 pounds.
Test Set, Fire Control System TS-3649/AWM-87 - The test set
3.7.2
shall meet the following requirements:
3.7.2.1
Form Factor - The overall dimensions of the test set shall not
exceed 14.5 inches wide by 12.75 inches high by 21 inches long.
Weight - The weight of the test set shall not exceed 55 pounds.
3.7.2.2
Content - The test set shall include a power cable, circuit card
3.7.2.3
extender hoard, card extractor and power cable adapter stored in the cover.
External Connectors - External connectors shall provide for the
3.7.2.4
following:
Reference
Function
Designation
Connector Type
Interface with missile
MS3102R28-2IP
Jl (W5P1)
launch stations
MS3102R32-2O1O-1OP
J2 (W12P2)
Interface with radar
access panel connectors
MS3102R32-2O1O-1OPW
J3 (W13Pl)
Primary power in
MS3102A-2O-4P
J4
-15-
|