| ![]() MIL-T-85068(AS)
Test lamps
LAMP TEST (Momentary SW)
Selects initial range, range rate
TEST MODE(Rotary)-Target Gen
and target OFF
Select target dynamics
TEST SELECT (Rotary)- Target
Gen
3.7.3.6
Status Indicators - The following status lights, indicators
and readouts shall be provided:
Function
Display
Output Trigger
OUTPUT
Primary power ON
POWER
Indicate cable condition
G0/NO-G0
Pin number indication
STEP NO.
Finish - Front panel finish will be black anodized per
3.9
MIL-A-8625, black, Class 2, Type 2.
Interchangeability - Interchangeability at major module level
3.10
shall be in accordance with MIL-STD-454, requirement 7.
Workmanship - Workmanship shall be in accordance with
3.11
MTL-STD-454, requirement 9.
4.
QUALITY ASSURANCE PROVISIONS
General - The test equipment shall be subjected to the following
4.1
tests to determine compliance with all the applicable requirements.
a.
Preproduction Tests
b.
Acceptance Tests
c.
Environmental Qualification Tests
Preproduction Tests - Preproduction tests shall be made on one
4.2
or more test equipments representative of the production equipments to be supplied under
the contract. Pre-production tests shall consist of the following:
a.
Demonstration tests
b.
Fleet approval tests
-19-
|