MIL-T-85378(AS)
3.4.8.7 Radiated emissions, 14 KHz to 10 GHz, electric field, RE02.
Radiated emissions shall be within the limits of MIL-STD-461, Test Method
RE02, over the frequency range of 14 KHz to 10 GHz.  Radiated emissions due tc
switching transients shall be within the limits of figure 4 over the frequency
range of 14 KHz to 10 GHz.
3.4.8.8 Conducted susceptibility, 30 Hz to 50 KHz, power leads, CSO1,
The test set shall not be susceptable to signal of 30 Hz to 50 KH z injected on
28 volt dc and 115 volt ac power leads at rms voltage levels of figure 5.
3.4.8.9 Conducted susceptibility, 50 KHz to 400 MHz, power leads, CS02.
O MHz
The test set shall not be susceptable to signals from 50 KHz to
injected on the 28 volt dc and 115 volt ac power leads at rms voltage levels
of less than 0.5 volts from a 50 ohm source.
3.4.8.10 Conducted susceptibility, spike, power leads, CS06. The test
set shall not be susceptib le to spike interference injected on the dc and ac
power leads in accordance with MIL-STD-462, Test Method, CS06.
3.4.8.11 Radiated susceptibility, 30 Hz to 30 KHz, magnetic field, RS01.
Hz to 30 KHz
The test set shall not be suseptible to radiated signals from
as specified in MIL-STD-461 Test Method RSO1.
3.4.8.12 Radiated susceptibility, magnetic induction field, RS02. The
test set shall not be susceptible to radiated fields as specified in
MIL-STD-461 Test Method RS02.
3.4.8.13 Radiated susceptibility, 14 KHz to 10 GHz, electric field, RS03.
The test set shall not be susceptib le to radiated fields as specified in
MIL-STD-461 Test Method RS03, except radiated levels shall be as indicated in
table 1.
TABLE I.
Radiated susceptibility levels
3.4.9 Safety.  The contractor shall ensure that safety requirements are
in accordance with MIL-T-28800.
3.4.9.1 Human performance/Human engineering. The test set and all
component parts thereof, shall be designed in accordance with the requirements
of MIL-STD-1472.  Recognized principles of human engineering as specified in
MIL-H-46855 shall be followed during design.