MIL-V-24694(SH)
5.3.1 Special marking.  Preserved assemblies shall be tagged, and the
individual unit container and exterior shipping container marked or labeled
with the following:
Tags :  "DO not disassemble.  The interior of this item has been
cleaned and examined and is coated with corrosion-preventative
compound (brand name and Military Specification number), manu-
factured by (name of company).  It was preserved on (date) and
should be represerved (number of months) months from date if
still in storage.  Preservation replacement can be done by
(state procedure)."
5.3.1.1 When the preservative fluid conforms to MIL-H-6083, the following
additional information shall be added to the tag:  "Removal of residual preser-
vative fluid prior to installation in petroleum base systems is not required."
5.3.1.2 When the preservative fluid conforms to MIL-H-19457, the following
additional information shall be added to the tag:  "Removal of residual preser-
vative fluid prior to installation in phosphate ester systems is not required."
5.3.1.3 When the preservative fluid conforms to E. F. Houghton Rust Veto
4221 (or equal) in water glycol, the following additional information shall be
added to the tag:  "Removal of residual preservative fluid by flushing with
system fluid is required prior to installation."
6.
NOTES
6.1  intended use.  The valves described in this Specification are Intended
for use in hydraulic systems operating at a maximum set pressure of 35 bars
differential).  The valves have an operating temperature range of
(500
minus 40 to 135C and are intended for use with petroleum base, water-glycol and
MIL-H-194S7 phosphate ester base hydraulic fluids.
6.2 Ordering data.
Acquisition documents should specify the
6.2.1 Acquisition requirements.
following:
(a)
Title, number, and date of this specification.
Title, number, and date of the applicable specification sheet.
(b)
(c)
Applicable specification sheet part number.
(d)
If drawings are required (see 3.8).
Level of preservation, packaging and packing (see 5.1 and 5.2).
(e)
(f)
preservatives fluid if other than specified (see 5.1.1.2).