| MIL-V-62358(AT)
specified tests. Control test verification for the two remaining assemblies shall be limited to
parameters directly related to failure cause and parameters affected by corrective action taken.
4.6 Methods of inspection.
4.6.1 Coil resistance. To determine conformance to 3.5.1, resistance of the solenoid valve
coil, when measured between solenoid connector and ground, shall be not less than 60 ohms nor
more than 70 ohms.
4.6.2 Pull-in voltage. To determine conformance to 3.5.2, supply oil conforming to
MIL-L-21260, Grade 10, which conforms to MIL-L-2104, Grade 10, with 135 to 270 ppm
biocide, at 250 + 100F through a feed orifice 0.037 + 0.001 inch diameter by 0.25 + .02 inch long
under pressure of 90 + 5 psi, to verify that valve opens at not more than 18 volts and recloses
when voltage is reduced to not less than 1 volt.
4.6.3 Bleed rate. To determine conformance to 3.5.3, after energizing valve to 30 + 1 volt,
supply oil conforming to MIL-L-21260, Grade 10, which conforms to MIL-L-2104, Grade 10,
with 135 to 270 ppm biocide, at 250 + 100F through a feed orifice 0.037 + 0.001 inch diameter by
0.25 + .02 inch long under pressure of 150 + 5 psi, to verify that pressure in the cavity between
orifice and valve does not exceed 18 psi.
TABLE II. Classification of tests.
Preproduction
Acceptance
Control
/Initial Prod.
Tests 100
Tests -
C
Title
Requirements
tests
percent
1/500
oil resistance
3.5.1
4.6.1
4.6.1
Pull-in voltage
3.5.2
4.6.2
4.6.2
Bleed rate
3.5.3
4.6.3
4.6.3
Valve leakage
3.5.4
4.6.4
4.6.4
Planar function
3.5.5
4.6.5
4.6.5
Endurance
3.5.6.1
4.6.6.1
4.6.6.1
Low temperature
3.5.7.1
4.6.7.1
4.6.7.1
High temperature
3.5.7.2
4.6.7.2
4.6.7.2
Thermal shock
3.5.7.3
4.6.7.3
4.6.7.3
Basic shock
3.5.7.4
4.6.7.4
4.6.7.4
Gun firing shock
3.5.7.5
4.6.7.5
4.6.7.5
Vibration,
3.5.7.6
4.6.7.6.1
4.6.7.6.1
sinsuoidal
Vibration, random
3.5.7.7
4.6.7.6.2
4.6.7.6.2.1
4.6.4 Valve leakage. To determine conformance to 3.5.4, with solenoid in de-energized
condition, supply oil conforming to MIL-L-21260, Grade 10, which conforms to MIL-L-2104,
Grade 10, with 135 to 270 ppm biocide, at 250 + 100F, through a 0.037 + 0.001 diameter by
0.25 +.02 inch long orifice under pressure of 150 + 5 psi, to verify that valve leakage in a cavity
between the orifice and valve does not exceed 10 psi.
9
|