MIL-V-62475(AT)
TABLE VIII. Classification of defects.
Method of
Category
Defect
examination
Major
AQL 25 Defects/100 units
101
Stowage, damage clearance improper (see 3.4.2).
Visual and
functional
Visual and
102
Welding malfunction, damage, structural defects, weld repairs
functional
without authorization or beyond scope of authorization (see 3.4.5).
Visual and
Vehicle performance, improper mounting, leaks 1/
103
functional
malfunction, damage, improper clearance (see 3.5.2).
Visual and
Sealing, malfunction, damage leaks (see 3.5.9).
104
functional
Visual and
Bearings, malfunction, damage improper fit (see 3.5.9.2).
105
functional
Visual and
Hatches, malfunction, nonconform, leaks damage, (see 3.5.14).
106
functional
Visual and
Ramp system, malfunction, leaks, damage, improper fit
107
functional
(see 3.5.15).
Visual and
Bilge pumps, malfunction, damage (see 3.5.16).
108
functional
Visual and
Trim vane, malfunction (see 3.5.17).
109
functional
Visual and
Vision devices, malfunction, damage (see 3.5.19).
110
functional
Visual and
Targeting station, erection arm, cupola; malfunction, damage,
111
functional
improper clearance, structural and welding defects (see 3.5.20).
Visual and
AZ and EL drive system, malfunction, damage (see 3.5.20.2.2).
112
functional
Visual and
TSCD, malfunction, damage, improper indicators (see 3.5.21).
113
functional
Visual and
Electrical system, components, circuits and communication system
114
malfunction, improper improper lighting sequence (see 3.5.25). 2/
functional
Hydraulic control system, malfunction, damage leaks (see 3.5.27).
Visual and
115
functional
Manual hydraulic pump, malfunction, damage, improper clearance
Visual and
116
(see 3.5.27.3.1)
functional
Controls malfunction, improper clearance (see 3.5.28).
Visual and
117
functional
Visual and
Safety interlocks, malfunction, damage (see 3.5.29).
118
functional
30