| ![]() MIL-V-82440(OS)
d.
Acceleration (packed and packaged):
5 to 60 cps
1g
Automatic cycling the range:
e.
O to 15 minutes (optional)
f.
Temperature chamber range:
-45 F to +140 F accuracy
to 5F
Interior size:
2-1/2inches x 3-1/2 inches.
g.
x 5-1/2 inches minimum
.
4.4.3.2
Acceleration equipment.
The acceleration equipment shall
have the following characteristics:
35 g's with a 1 pound test specimen.
4.4.3.3
Shock equipment. The shock equipment shall be capable of
accepting a 1 pound test specimen and shall provide ranges of:
a.
300 g's for 0.5 millisecond (ins) to 1.5 ms
b.
60 g's for 8.0 ms to 10.0 ms
c.
45 g's for 18.0 ms to 20.0 ms
4.4.3.4
Temperature and humidity conditioning equipment, One or
more equipments may be utilized to provide the following characteristics:
-45 F to +140 F; with an
a.
Temperature:
accuracy to 5 F
b.
Relative humidity:
95 percent minimum at +110 F;
with an accuracy to 5 F
c.
Interior size:
2-1/2 inches x 3-1/2 inches x
5-1/2 inches minimum
This equipment may be used for both non-operating and ready/operating
temperature (and humidity) tests.
4.4.4
Test Procedures.
Operational test. The valve shall be subjected to the
4.4.4.1
acceptance tests detailed in 4.5.4.1 and 4.5.4.2.
|