| ![]() MIL-V-82440(OS)
Temprature and humidity, non -operating condition. Tempera-
4.6.3.4
ture and humidity testing of the valve, in the non-operating condition,
shall be performed in accordance with 4.4.4.5.
4.6.3.5
High temperature operating. The valve shall be subjected to
the high temperature operating test in accordance with 4.4.4.7.
Low temperature operating. The valve shall be subjected to
4.6.3.6
the low temperature operating test in accordance with 4.4.4.6.
4.6.3.7
Operational tests. The valve shall be subjected to the
and 4.5.4.2.
operational tests of 4.5.4.1
4.6.3.8
Operational service life. The valve shall be subjected to
the operational service life tests in accordance with 4.4.4.10.
Test data. Test data shall be recorded in accordance with
4.6.4
4.4.5, as appropriate, and maintained as a part of the inspection record.
Determination of defect or failure. Failure of the valve to
4.6.5
successfully pass the tests in 4.6.3.1 through 4.6.3.8 shall be cause
for withholding acceptance of all units on hand. Corrective action shall
be taken in accordance with 4.3.2.
4.7
Examination of first echelon repair parts.
General.
4.7.1
The information presented in this section is applicable to
4.7.1.1
all components assembled into the end product and to first echelon repair
The information is divided into the following major divisions:
parts.
a. Parts covered by separate CD's
b. Parts which are manufactured in accordance with
Federal or Military specifications which contain
adequate quality assurance provisions.
c. Minor hardware items