| MIL-V-82444A(OS)
TABLE IX
PERIODIC TEST SCHEDULE
4.6.1 Test conditions. Unless otherwise specified the valve shall be
subjected to the periodic tests under the following conditions:
Room ambient +32 F to +98 F
a.
Temperature:
Normal ground atmospheric pressure
b.
Altitude:
c.
Vibration:
None
Room ambient
d.
Humidity:
4.6.2 Test equipment and setup. The test equipment and setup for the
periodic tests shall be in accordance with 4.4.3.
4.6.3 Test procedures
4.6.3.1 Inspection, prior to firing. Inspection of the valve, prior
to firing, shall be performed in accordance with 4.5.6.1 through 4.5.6.4.
4.6.3.2 Vibration, ready condition. Vibration testing of the valve,
in the ready condition, shall be performed in accordance with 4.4.4.4.
4.6.3.3 Acceleration, ready condition. Acceleration testing of the
valve, in the ready condition, shall be performed in accordance with
4.4.4.5.
4.6.3.4 Shock, ready condition. Shock testing of the valve in the
ready condition, shall be performed in accordance with 4.4.4.6.