| MIL-W-43001F
(d) There shall be no leaks.
(e) Moving parts and bearings shall evidence no overheating.
(f) There shall be no failure of any component of the anti-vibration
mount (when required, see 3.5.1.21).
The assembled machines shall meet the following functional requirements when
tested as specified in 4.6.2 using cotton sheets, polyester-cotton sheets
conforming to Type V of DDD-S-281, or woolen blankets conforming to Type I or II
or MIL-B-844 and the applicable washing formula (see 4.6.2.1).
(1) The machines shall be capable of extracting water from saturated
sheets to a maximum moisture retention of 50 percent of the normal dry weight
(i.e, each 100 pounds of normal dry laundry shall be loaded into the machine,
saturated with water and extracted, so that the total weight of the laundry does
not weigh more than 150 pounds after 12 minutes extraction (see 4.6.2)).
(2) No water or soap solution shall back up or overflow through the
supply containers or vent pipe during extract cycles.
(3) There shall be no failure of any component of the antivibration
mount, if provided.
(4) There shall be no leaks during washing and extracting cycles.
(5) Moving parts and bearings shall not overheat.
(6) Sipplies are injected in the correct amounts and intervals
required by the formula selected (see 3.5. l.4(g)).
(7) There shall be no structural failures.
(8) Extraction speed (as applicable) is operable.
3.5.1 Wiring and controllers.
3.5.1.1 Wiring and instructions. Wiring shall be provided between motors,
controllers, txmers, pushbuttons, starter, and limit switches installed on the
equipment and shall be done with materials specified in 3.4.4, as applicable,
except metallic armored cable or liquid tight flexible conduit shall be used
where required for belt adjustment by moving a motor. Installation shall
conform to the requirements of the National Electrical Code. All wiring shall
terminate in connection boxes with provisions for connections beyond the
machine; each conductor shall be identified by a different color or clearly
labeled. Wiring and connection diagrams shall be furnished with each unit.