| ![]() MIL-W-44167B(GL)
TABLE I.
End item visual defects (cont'd)
Classification
Minor
Major
Defect
wiring cut , abraded, or not properly
Electrical assembly
112
installed or joined
Adequate slack not provided for
217
wiring to relieve strain
Missing; incorrect; incomplete;
Marking
illegible; of improper size,
location, sequence, or method of
113
application
This defect shall be scored as major when seriously affecting
serviceability or appearance and minor when affecting serviceability or
appearance but not seriously.
4.4.4 End item dimensional examination. The end items shall be examined
for compliance with dimensions as specif ied in this specification and on the
drawings . Only those dimensions that can be evaluated without damaging or
disassembling the end items shall be examined. Any dimension that is not
within the specified tolerance shall be classified as a defect. The lot size
shall be expressed in units of washing machines. The sample unit shall be
one washing machine. The inspection level shall be S-2 and the AQL,
expressed in terms of defects per hundred units, shall be 4.0.
4.4.5 End item testing. Each production end item shall be tested for the
characteristics listed in table II. Failure of any test shall be cause for
rejection of the end item.
End item tests
TABLE II.
17
|