| MIL-W-50987(MU)
all the equipment coded as "Contractor Design" in the number
column. These contractor designs must be approved by the Govern-
ment prior to fabrication or procuring of the equipment. Designs
shall be submitted for approval as specified in 6.3.5.
6.3.2 Inspection Equipment List codes. - The inspection
equipment as defined in 6.3.3 and 6.3.11 will be designated in the
EL by the Following codes:
CD - Contractor design 01) controlled contractor format
arid/or commercial equipment.
MU - Amy design, mandatory for use.
6.3.3 Army Designs. - Army designs are reflected on detailed
drawings which completely depict all the information necessary for
the fabrication of the item of inspection equipment. The contrac-
tor need provide no design when an Army design is listed for an
item of inspection equipment. Army designs fall into two basic
classifications; mandatory (designated "MU") and non-mandatory
(indicated by drawing or Federal Stock Number). When an inspection
equipment list references mandatory Army designs, the contractor
shall comply with, and use these designs accordingly. The con-
tractor may, however, in connection with non-mandatory designs,
and with the approval of the Government, design alternate inspec-
tion equipment or use comparable commercial equipment to facilitate
his operations. Such contractor prepared designs or commercial
equipment selections must be approved by the Government prior to
fabrication or procuring of' the equipment. Designs shall be sub-
mitted for approval as specified in 6.3.5.
6.3.4 Contractor Designs. - Contractor designs are designs
of inspection equipment for which the Government has assigned de-
sign responsibility to the contractor. Contractor designs shall
be supported by detailed drawings which depict all information
necessary to completely fabricate, calibrate and operate an item
of inspection equipment. This requires that the necessary views,
dimensions, materials, finish, notes, operating and calibration in-
structions be properly depicted in accordance with approved prac-
tices to the extent that further calculation or clarification will
not be required. Unless otherwise specified, contractor designs
may be developed on the format the contractor normally employs in
his equipment design procedure provided such format reflects the
detail and information specified above, subject to the following
controls: All submitted contractor designs shall conform to
MIL-D-1000, Category E, Form 2. Legibility and reproducibility
shall permit conventional making of clearly understandable, high
contrast reproductions . Contractors shall submit one copy of
final designs as a rolled set. Designs shall be submitted for ap-
proval as specified in 6.3.5.
11
|