MIL-P-46320C(MU)
3.9.3.2 Output voltage relative to input
maximum output voltage including the peak
voltage. At standard ambient temperature,
ripp]e voltage shall not exceed 16 Kilovolts
the power supply shall deliver the minimum
(KV) under any condition.
value of dc output voltage specified in Table
IV upon application of the prescribed value
3.9.3.4 Rise time. The prover supply shall
of dc input voltage under the three in-
deliver 15KV dc under a load current of
dicated load current conditions.
5 X 10-7 amperes in not more than 10 sec.
ends, immediately after application of its
o
TABLE I Electrical characteristics (+ 125 F.)
input voltage at the ambient temperatures
specified in 3.7.2.
3.9.3.5 Ripple. The peak to peak ripple
voltage of the power supply shall not exceed
one percent of its output voltage at the
ambient temperatures specified in 3.7.2.
3.10 Operability. The power supply shall
TABLE II. Electrical characteristics
not be damaged or adversely affected and
o
o
(+60 to +90 F)
shall meet the requirements of 3.9 after
being subjected at standard ambient temper-
ature to one hour of continuous operation
followed by the electrical shock imposed by
one hour of intermittent operation. Inter-
mittent operation shall consist of one minute
cycles; with each cycle consisting of 30
seconds "on" and 30 seconds "off." The
power supply output terminals shall be
shorted out during each "off" portion of
TABLE III. Electrical characteristics (-40F.)
the cycle.
3.11 Minimum operating life. The power
supply, excluding battery, shall meet all re-
quirements of this specification after com-
pletion of 1000 hours of continuous opera-
tion at standard ambient temperature.
3.12 High voltage breakdown. The power
TABLE IV. Output vs input voltage
supply shall exhibit no evidence of corona,
o
(+60 to +90 F)
arcing, or spraying when meeting the re-
quirements of 3.9.
4. QUALITY ASSURANCE PROVISIONS
4.1 Responsibility for inspection. Unless
otherwise specified in the contract or pur-
chase order, the supplier is responsible for
the performance of all inspection require-
ments as specified herein. Except as other-
wise specified, the supplier may utilize his
3.9.3.3 Maximum output voltage. The
own facilities or any commercial laboratory
4