| MIL-A-21430B(OS)
Cable Assembly CA-1321, Drawing 3175691
Measure From
To
Plug P2, Contact
Plug Pl, Contact
R
1
3
P
s
4
8
T, V
4.6.2 D-C resistance (M102). Measure the d-c resistance through each
resistance path as indicated in the following tabulations, using an instru-
ment or instruments with the minimum requirements of 4.4.2 over the range
specified. Any measured d-c resistance outside the specified range shall
constitute a defect.
Cable Assembly CA-55, Drawing 1260785:
To
Measure From
Resistance
Plug S1, Contact
Plug Pl, Contact
(ohms
Remarks
R2
2
A
18,200
1.0%
1.5
3.0%
Rl
2
J
R3
7
B
17,800
1.0%
Cable Assembly CA-57, Drawing 1260787:
Measure From
To
D-C Resistance
Plug S1, Contact
(ohms )
Plug Pl, Contact
Remarks
10
3.0%
J
5
R1
5
76,000
1.0%
R2
A
7
6
74,000
1.0%
R3
B
7
Cable Assembly CA-58, Drawing 1260789
To
Measure From
D-C Resistance
Plug S1, Contact
(ohms )
Remarks
Plug Pl, Contact
J
450
3.0%
Rl
2
R2
A
279,000
1.0%
2
279,000
1.0%
R3
B
7
Cable Assembly CA-90, Drawing 1274694:
To
D-C Resistance
Measure From
Plug Pl, Contact
(ohms )
Remarks
Plug S1, Contact
A
2
17,750
1.0%
R2
2
1.0
5.0%
Rl
J
9
|