| MIL-A-21430B(OS)
Cable Assembly CA-91, Drawing 1274696:
To
D-C Resistance
Measure From
Plug S1, Contact
( ohms)
Plug Pl, Contact
Remarks
6
A
74,000
1.0%
R2
6
J
20
5.0%
R1
Cable Assembly CA-796, Drawing 883202:
To
Measure From
D-C Resistance
Terminal Lug
( ohms)
Plug Pl, Contact
Remarks
P2
(+135)
A
1,690,000
1.0%
Rl
P3
(+73 1/2)
917,000
1.0%
R2
B
c
P4
(+67 1/2)
842,000
1.0%
R3
P2
(+135)
H
R4
29800
5.0%
Cable Assembly CA-797, Drawing 893796:
Measure From
To
D-C Resistance
( ohms)
Remarks
Plug Pl, Contact
Terminal Lug
9.0
5.O%
P3
A
R1
36,500
1.0%
P3
R2
c
Cable Assembly CA-799, Drawing 883198:
To
D-C Resistance
Measure From
( ohms)
Remarks
Plug Pl, Contact
Terminal Clip
P2 (+3)
1.0%
36,500
N
A
P2 (+1 1/2)
17,750
1.0%
R2
B
62
5.0%
R3
P2 (+3)
H
Cable Assembly CA-1321, Drawing 3175691:
D-C Resistance
To
Measure From
( ohms)
Remarks
Plug P2, Contact
Plug PI, Contact
112,000
1%
w
A
3
36
1%
R1
H
3
10
|