4.6.3 Insulation resistance (M103).  After the completion of the specified 
conditioning period (see 3.3.3), measure the insulation resistance between 
each circuit and every other circuit, not connected by design, and to 
ground (defined in 3.3.3).  The insulation resistance measurements shall 
be made, using an instrument having the minimum requirements specified in 
4.4.3, in accordance with the following tabulations. Any measured resistance 
less than 500 megohms shall constitute a defect. 
Cable Assemblies CA-55, Drawing 1260785, 
CA-57, Drawing 1260787 and CA-58, Drawing 
1260789: 
Measure From 
To 
Plug S1, Contact 
Plug S1, Contact 
T 
P, R, S and ground 
P 
R, S and ground 
s 
R and ground 
R 
ground 
Cable Assemblies CA-90, Drawing 1274694 
and CA-91, Drawing 1274696: 
Measure From 
To 
Plug S1, Contact 
Plug S1, Contact 
T 
P, R, S and ground 
P 
R, S and ground 
S and ground 
R 
s 
ground 
Cable Assembly CA-797, Drawing 893796: 
To 
Measure From 
Terminal 
Terminals 
P3 and ground 
P2 
P3 
ground 
Cable Assembly CA-796, Drawing 883202: 
Measure From 
To 
Terminals 
Terminal 
P3, P4, P5 and ground 
P2 
P4, P5 and ground 
P3 
P4 
P5 and ground 
P5 
ground 
11 
 | 
| 
 