| MIL-A-23622
Individual tests - Each actuator submitted for acceptance
4.4.1
under contract shall be subject to the following tests as described under
section on test methods (4.6) in the sequence listed. Actuators not meeting
the requirements of these tests may be corrected prior to resubmitting them
for acceptance. Before resubmission, full particulars concerning previous
rejection and corrective action shall be furnished the government inspector.
(a) Examination of product (4.6.1)
.
(b) Acceptance operational check (4.6.2.1)
(c) Stall Force (4,6.3).
In addition, any actuator shall be subject, with the
approval of the procuring activity, to any other tests specified herein
which the Government inspector considers necessary to determine unit com-
pliance with the requirements of this specification.
Sampling tests
4.4.2
Sampling plan - Actuators shall be selected at random.
4.4.2.1
From each lot submitted for acceptance and subjected to the static limit
load test (4,6.5) In accordance with the following sampling plan:
Sample size
Lot Size
2
o-99
3"
100 - 29$
4
300 - 500
A lot shall consist of actuators of the same type, pro-
duced under essentially the same manufacturing conditions, and submitted
for inspection at one time. The unit of inspection shall be one actuator.
Standard test conditions - Unless otherwise specified
4*5
herein, all tests shall be conducted at the ambient temperature, pressure,
and humidity conditions specified in MIL-E-5272.
Test
me--
4.6
Examination of product - The actuator shall be examined
4,6.1
to determine conformance to this specification and the applicable MS draw-
ing with respect to material, workmanship, dimensions and markings.
.
12
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |