4.2 Classification of inspections. The inspection requirements specified
herein are classified as follows:
a. First article inspection (see 4.3).
b. Quality conformance inspection (see 4.4).
4.3 First article inspection. First article inspection shall consist of all
the inspections listed in Table I. First article inspection report format
shall be in accordance with MIL-STD-831 (see 6.2.2).
First article inspection - schedule and sequence. 1/
TABLE 1.
1/ Inspection sequence is denoted by the number in the same
columns. An X denotes inspection is not required.
4.3.1 Sample. First article actuator sample shall consist of the first five
actuators manufactured on contract. The actuators shall be permanently
labeled A, B, C, D, and E for ease of identification. Failure of the
actuators to pass any of the first article inspections shall be cause for
r e j e c t i o n (see 6.2.1h).
4.4 Quality conformance Inspection. Quality conformance inspection shall
consist of the following inspections:
a. Individual inspections (see 4.4.1).
b. Sampling inspections (see 4.4.2).
Quality conformance inspection report format shall be in accordance with
MIL-STD-831 (see 6.2.2).
5
|